Sign In | Join Free | My webtextiles.com |
|
Brand Name : Sinuo
Model Number : SN886
Certification : Calibration Certificate (Cost Additional)
Place of Origin : China
MOQ : 1
Payment Terms : T/T
Delivery Time : 45 days
Price : Customized
Supply Ability : 10 sets/month
Packaging Details : Other
Applied Standard : IEC60068 series
Effective Volume : Can be customized
Temperature Range : Can be customized
Temperature Variation : ±2℃
Humidity Range : 30%〜98%RH
Humidity Variation : ±5.0%RH
Heating Rate : ≥2.5°C/min
Cooling Rate : Average 1.0℃/min
IEC 60068 Temperature Humidity Walk In Environmental Test Chambers
Complied Standards & Clauses
IEC 60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”
IEC 60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”
IEC 60068-2-14:1984 "Basic environmental testing procedures-Part 2: Tests-Test N: Change of temperature, IDT"
IEC 60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle) , IDT”
IEC 60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”
IEC 60068-3-1:1974, "Basic environmental testing procedures-Part 3: Background information -Section 1: Cold and dry heat tests"
IEC 60068-3-1A:1978, First supplement to publication 60068-3-1, IDT) and etc.
Equipment Overview
It is used to make the test of high and low temperature, damp and heat tests on electrical, electronic, mechanical and large parts, semi-finished products, and finished products. To test the quality and productivity of products, spare parts under simulated temperature and humidity conditions.
Installation environment:
Temperature: 0℃~35℃, relative humidity: ≤85%, air pressure: 86kPA~106kPa.
Please confirm that the installation site should be level, well ventilated, and without strong vibration around the equipment. There has no strong electromagnetic filed, without flammable, explosive, corrosive substances and dust around this equipment. It should leave enough space for use and maintenance.
Technical Parameters
Standard volume(m³) | 8 | 12 | 80 | 125 |
Internal chamber size (W*H*D) m | 2×2×2 | 3×2×2 | 4×4×5 | 5×2×5 |
Temperature range | The highest test temperature: 80℃, 120℃; the lowest test temperature: -60℃, -40℃, -20℃, 0℃ | |||
Humidity range | 30%~98%RH | |||
Temperature variation | ±2℃ | |||
Temperature uniformity | ±2℃ | |||
Temperature fluctuation | ±0.5℃ | |||
Humidity variation | ±5.0%RH | |||
Heating rate | ≥2.5°C/min (Non-linear, no load) | |||
Cooling rate | Average 1.0℃/min | |||
Internal chamber material | SUS304 stainless plate | |||
External chamber material | A3 cold-rolled steel plate with electrostatic double-sided spraying /SUS304 stainless steel | |||
Insulation material | Rigid polyurethane foam | |||
Cooling method | Water-cooled (adopt German Bitzer fully enclosed compressor or German Bock semi-hermetic compressor) | |||
The refrigerant | R404a, R23 | |||
Temperature and Humidity sensor | A grade PT100 platinum resistance | |||
Heater | Nickel-chromium alloy electric-heating heater | |||
Humidifier | Adopt external humidification method | |||
Power supply | 380V±10%V;50Hz;or match client's local power supply re | |||
Protection System | Power supply phase loss and phase sequence error protection, water shortage automatic alarm protection, leakage protection, heater over temperature protection, heater short circuit and other overcurrent protection |
![]() |
IEC 60068 Temperature Humidity Walk In Environmental Test Chambers Images |