Sign In | Join Free | My webtextiles.com
China Sinuo Testing Equipment Co. , Limited logo
Sinuo Testing Equipment Co. , Limited
Sinuo Testing Equipment Co., Limited
Verified Supplier

4 Years

Home > Walk In Environmental Test Chamber >

18m³ Walk-in Constant Temperature And Humidity Test Chamber IEC60068-2-30

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

18m³ Walk-in Constant Temperature And Humidity Test Chamber IEC60068-2-30

Brand Name : Sinuo

Model Number : SN886-18F

Certification : Calibration Certificate (Cost Additional)

Place of Origin : China

MOQ : 1

Price : Customized

Payment Terms : T/T

Supply Ability : 1 sets/month

Delivery Time : 45 days

Packaging Details : Other

Effective volume : 18m³

Cooling method : Water cooling

Inner box size : W3000 mm*H2000 mm*D3000mm

Outer box size : W3800 mm*H2530 mm*D3690 mm

Temperature range : 0°~ +100℃

Humidity range : 20%-98%RH

Heating rate : 2~3℃/min

Cooling rate : 0.7~1℃/min

Contact Now


18m³ Walk-in Constant Temperature and Humidity Test Chamber IEC60068-2-30

Complied Standards & Clauses


Conforms to:

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

Equipment Overview



The walk-in constant temperature and humidity test room is suitable for safety performance testing of electronic components, providing reliability testing, product screening testing, etc. At the same time, through this test, the reliability of the product is improved and the quality control of the product is carried out. The walk-in constant temperature and humidity laboratory is an essential test equipment in the fields of aviation, automobiles, home appliances, scientific research, etc. It assesses and determines the parameters and performance of electrical, electronic, semiconductor, communication, optoelectronics, electrical appliances, automotive electrical appliances, materials and other products after the temperature environment changes rapidly during high and low temperature and humidity tests, and the adaptability of use. It is suitable for schools, factories, military industry, research and development and other units.


Technical Parameters


1.Product name Walk-in Constant Temperature and Humidity Test Chamber
Mode SN886-18F
2.Applicable instructions
Applicable range The walk-in constant temperature and humidity test room is suitable for safety performance testing of electronic components, providing reliability testing, product screening testing, etc. At the same time, through this test, the reliability of the product is improved and the quality control of the product is carried out. The walk-in constant temperature and humidity laboratory is an essential test equipment in the fields of aviation, automobiles, home appliances, scientific research, etc. It assesses and determines the parameters and performance of electrical, electronic, semiconductor, communication, optoelectronics, electrical appliances, automotive electrical appliances, materials and other products after the temperature environment changes rapidly during high and low temperature and humidity tests, and the adaptability of use. It is suitable for schools, factories, military industry, research and development and other units.
3.Volume and size
3.1. Effective volume 18m³
3.2. Inner box size W3000 mm*H2000 mm*D3000mm
3.3. Outer box size About W3800 mm*H2530 mm*D3690 mm(Excluding unit size)
4.Performance
4.1. Cooling method Water cooling
4.2. Temperature range 0°~ +100℃
4.3. Humidity range 20%-98%RH
4.4. Heating rate 0°~ +100℃ About 2~3℃/min (no load, average)
4.5. Cooling rate +100℃~0℃ About 0.7~1℃/min (no load, average)
4.6. Analysis accuracy 0.01℃
4.7. Temperature fluctuation ±0.5℃
4.8. Temperature deviation ±2.0℃
4.9. Humidity deviation ≤±5.0%RH below 75%RH, ≤+2/-3%RH above 75%RH
4.10. Humidity fluctuation ≤±2.0%R.H
4.11. Temperature and humidity control capability range diagram 18m³ Walk-in Constant Temperature And Humidity Test Chamber IEC60068-2-30
4.12. Power supply AC3¢5W 380V 50Hz (R, STN three-phase five-wire plus ground wire) (voltage fluctuation ≤±10%)
4.14. Test standards

GB-2423.1-2008 (IEC68-2-1) Test A: Low temperature test method.

GB-2423.2-2008 (IEC68-2-2) Test B: High temperature test method.

GB2423.3-2008 (IEC68-2-3) Test Ca: Constant damp heat test method.

GB2423.4-2008 (IEC68-2-30) Test Db: Alternating damp heat test method.

GB 11158 "Technical Conditions of High Temperature Test Chamber"

GB10586-1 "Technical Conditions of Humidity and Heat Test Chamber"

4.15. Power The total power of the equipment is about 25KW
4.16 Noise Measured according to GB/T14623-2008, noise ≤75dB (noise detection device is measured 1m away from the equipment door)
4.17 Energy-saving design The PLC (Programmable Logic Controller) of the control system automatically adjusts the operating conditions of the refrigerator according to the test conditions. The refrigeration system can adjust the power according to the load and has compressor energy adjustment technology, which can achieve excellent energy-saving effects.

Details

18m³ Walk-in Constant Temperature And Humidity Test Chamber IEC60068-2-3018m³ Walk-in Constant Temperature And Humidity Test Chamber IEC60068-2-30


Product Tags:

Constant Temperature and Humidity Test Chamber

      

IEC60068-2-30 Temperature And Humidity Test Chamber

      
Quality 18m³ Walk-in Constant Temperature And Humidity Test Chamber IEC60068-2-30 for sale

18m³ Walk-in Constant Temperature And Humidity Test Chamber IEC60068-2-30 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)